Radina Tau V5
Radina Tau V5 is a communication device with the
main purpose to transmit data from security panels and/or sensors through VHF radio channel
and/or IP based network. Combining the advantages of those two advanced communication
technologies Radina Tau V5 provides the most secure connection with monitoring center using
various ways of back-up – 1 main and up to 4 back-up VHF radio frequencies and up to 4 IP
servers.
- Power supply 12VDC (8,5V to 16V)
- Low power consumption
- Frequency range – from 136MHz to 174MHz
- RF Output power – 37,5dBm (± 1,5dB) in the whole RF range
- Bandwidth – 12,5KHz
- Constant RF output power regardless of the power supply voltage - from 8,5V to 16V
- Protocols - LARS, LARS II
- One main and up to four back-up frequencies
- Configurable parity check, RF messages repeat count, RF test repeat count, test period and
“repeat until restore” period, usage of a Smart Test to reduce radio transmitting
- Capability every digital input separately to be set to transmit on backup RF frequency
- Capability every digital input separately to be set to re-transmit RF message over a period
of time until it is in alarm state
- Network interface - IEEE 802.3 Ethernet, Fully Compatible with 10/100/1000BaseT Networks
- Static or dynamic IP address compatible with DHCP server
- Capability to use one or two fully independent IP servers
- Encrypted connection with IP servers
- Verification with an unique ID code
- HTML server for easy configuration and status check, protected with an username and a
password
- Capability to change the username and password of the html server
- Indication (4 LEDs) for:
- Radio LED – blinks under normal operation, ‘ON’ when transmitting radio message, ‘OFF’
while waiting after transmission
- LAN Status - Ethernet available
- LAN Activity – Network packets service
- Server LED – Established connection with IP server/s – when using 1 server - ‘ON’ when
connection is established. When using 2 servers - ‘ON’ when connection is established
with both servers, blinks if connection is established with only one server , ‘OFF’ when
connection isn’t established with both servers
- Six digital inputs working simultaneously with RF and IP transmitters
- Capability to use communicator as input - using “Ademco Contact ID” protocol
- Configurable working mode for every digital input:
- Normal Open
- Normal Close
- Check for AC voltage from 5V to 20V
- Deactivated
- Configurable parameters sent for events on each digital input to IP servers